What the Work Includes

Pellet units depend on moving parts and electronics more than any other fireplace appliance. A jammed feed screw, a worn igniter, a tired exhaust fan, a dirty sensor or a failing board can each stop the fire. We test them in order and replace what failed. The vent gets cleaned too, since fly ash in the pipe trips the safety switches. If the repair bill nears the cost of a new unit, we price both.

Feed screw and motor freed or replaced
Igniter tested with a meter
Exhaust and room fans serviced
Sensors and control board looked at
Fly ash cleared from the vent pipe
Repair and replacement priced together

How a Pellet Unit Fails

A pellet stove or insert turns a bag of pellets into heat through a chain of parts, and a fault anywhere in the chain stops the whole thing. Pellets wait in a hopper. A screw-shaped feeder, turned by a small motor, moves them into a burn pot. An electric igniter heats the air in the pot until the pellets catch. A draft blower draws air into the pot and drives the flue gases outside; a second blower circulates house air across the heated firebox. A circuit board runs all of this, reading a handful of switches and probes that report if a flame is burning, if the vent is open and if any part is overheating. When one link breaks, the board usually shuts the unit down and, on many models, shows a code. Our work starts with that code and the story you tell us about what the stove did before it stopped.

The faults we find most in La Mirada homes fall into a few groups. Feed problems come from jammed pellets, a worn motor or pellets that are too long or dusty, and they show up as a fire that starves and goes out. Ignition problems come from an igniter that has burned out or a burn pot so caked with ash that air cannot reach the pellets. Fan problems make noise first, then slow down, then stop. Sensor and switch problems often follow a dirty vent, since the unit is built to shut off when it senses poor draft. Many repairs need only a part and a thorough cleaning. We test the suspect part before replacing it, so you do not pay for guesses, and we explain the cause so it is less likely to happen again.

Cleaning, Venting and When to Replace

Pellets leave fine ash, and a pellet unit that is not cleaned out runs worse each week until it stops. Fine ash settles wherever air slows down: the pot itself, the narrow channels that warm the room air, and the exhaust pipe leading out. A full service clears all three, plus the fans and the hopper. The vent deserves special mention. Pellet units vent through a smaller pipe than wood stoves, often out a wall, and a run with too many bends or too little rise can leave the stove short of draft. Where a pellet insert vents up an old masonry chimney, it needs a proper liner to the top, not a short pipe that ends a foot above the damper. If yours was installed that way, we will flag it and price the fix.

Pellet stoves have a long life when they are looked after, but parts and boards for some older or less common models are hard to source. When we find that a repair depends on a part that is no longer made, or the firebox shows cracks or burn-through, we say so and lay out the options: a new pellet unit, a switch to a gas insert, or a wood insert if that fits how you live. Each comes with a different running cost and level of upkeep, and we go through them with you. For owners in Lakewood, Whittier and La Mirada, booking is done through the contact page. Say whether it stands on the floor or sits in a fireplace, which brand built it, and what it did just before it quit.

How Braxton Chimney Works Works

NFPA 211 Levels

The inspection level picked to match the plan for the flue

Sized to the Unit

Liners and clearances taken from the appliance manual

Figures on Paper

Options and costs written down before anything is ordered

Photos in the Report

Pictures of what we found and what we fitted

Other Services to Compare

Chimney Sweep

Brushing, a filtered vacuum and a written note on the flue before an insert, gas logs or another season of open fires.

Open →

Chimney Inspection

NFPA 211 Level 1, 2 or 3, written to answer one question: can this chimney take the upgrade you have in mind?

Open →

Chimney Repair

Brick, crown, cap and flue repairs that clear the way for an insert, a stove or a log set to go in.

Open →

Fireplace Inspection

Measured, inside-the-house look at firebox, damper, hearth and surround, done before you choose between an insert, logs or staying open.

Open →

Fireplace Repair

Firebox, damper and hearth repairs, done so the fireplace can stay open now or take an insert later without rework.

Open →

Chimney Level 2 Inspection

Camera inspection from firebox to cap, with attic and roof checks, booked before relining, fitting an insert or selling.

Open →

Chimney Cap Installation

Stainless or copper caps fitted over the flue, or over a new liner's top plate once an insert goes in.

Open →

Chimney Flashing Repair

New step and counter flashing where chimney meets roof, cut into the mortar rather than smeared on with sealant.

Open →

Chimney Masonry Repair

Repointing, brick replacement and flaked face repair, with a mortar soft enough to suit the brick already in the wall.

Open →

Chimney Rebuilds

Upper stacks or whole chimneys relaid when the brick has loosened, often with a liner sized for a planned insert.

Open →

Fireplace Cleaning

Firebox emptied of ash, then soot and smoke staining wiped from the glass doors and the face around the opening.

Open →

Gas Fireplace Cleaning

Yearly service for gas logs, inserts and direct-vent units: burner, pilot, glass and vent looked after in one visit.

Open →

Gas Fireplace Repair

Pilot, ignition, valve and fan faults on gas inserts, log sets and built-in gas fireplaces, found by testing first.

Open →

Fireplace Remodel

A new face, hearth and mantel designed together with the insert or gas unit that will sit inside them.

Open →

Fireplace Inserts

Wood, gas and pellet inserts compared, sized to your opening and fitted with a liner up to the top of the chimney.

Open →

Wood Stove Repair

Door rope, glass, baffles, firebrick and combustors renewed on wood stoves and wood inserts, plus the joint to the flue.

Open →

Gas Logs

Log sets chosen for your firebox and the way you use the room, with the gas line and venting checked first.

Open →

Chimney Seismic Retrofit

Bracing, strapping or a lighter rebuild above the roof for brick chimneys at risk in a strong quake.

Open →

Chimney Crown Repair

Split crowns sealed or poured new, so rain stays off the brick and out of the space around a new liner.

Open →

Dryer Vent Cleaning

Lint cleared from the dryer duct between the machine and the outside hood, with airflow confirmed at the end.

Open →

Chimney Liner Installation

A stainless liner matched to the appliance outlet, so an insert, stove or gas unit vents cleanly out the top.

Open →

Chimney Leak Repair

Damp stains, drips and rust in the firebox followed back to where the water enters, then fixed there.

Open →

Chimney Waterproofing

A breathable repellent for thirsty brick, used as the last step once the masonry repairs are finished.

Open →

Chimney Damper Repair

Throat dampers freed, rebuilt or replaced, and top-mounted dampers fitted where an open fireplace stays in use.

Open →

Chimney Chase Cover

Sagging or rusted tops on framed chimneys swapped for a stainless cover made for that chase.

Open →