Professional chimney service

Keep a Wood Stove Burning Clean, or Plan Its Successor

Start With the Fireplace

Insert Options Compared
Written Quote Before Work
Photos With Every Report
NFPA 211 Inspection Levels
Liners Sized to the Appliance
Based in La Mirada
Insert Options Compared
Written Quote Before Work
Photos With Every Report
NFPA 211 Inspection Levels
Liners Sized to the Appliance
Based in La Mirada

What the Work Includes

Wood stoves and wood inserts wear in predictable spots. Door rope dries out and leaks air, glass cracks, baffles warp, firebrick crumbles and catalytic combustors clog. Any one of these makes the stove burn too hot, smoky or short. We replace the worn parts, check the hearth and wall clearances, and look at the stovepipe or liner joint, a spot where smoke can slip into the room.

Door and glass rope renewed
Cracked stove glass replaced
Warped baffles and crumbled firebrick swapped
Catalytic combustor cleaned or replaced
Pipe or liner joint resealed

What Wears on a Wood Heater

Air is the throttle on any wood burner, stove or insert alike, and almost every repair we make comes back to it. Every door and window on a stove is sealed with braided fiberglass cord. Years of heat turn that cord stiff and thin, and stray air slips in around it. The stove then burns hotter and faster than you set it, and logs that should last the evening are gone in an hour. Up near the roof of the firebox sits a baffle of steel, ceramic board or brick, holding the hot gases back long enough to finish burning. When it cracks or slips, the stove burns dirtier and puts more creosote in the flue. The firebrick lining protects the steel shell; cracked or missing bricks let heat warp the metal behind them. Newer stoves also have air tubes or a catalyst that need checking.

We look at all of those parts on a repair visit and replace the ones that are worn. The stove pipe, or the liner on an insert, gets the same attention: joints should be tight and fastened, and the pipe should have the right clearance to walls and ceilings. A lot of stoves in La Mirada came with the house, and their history is unknown. In those cases we also check that the stove is set on a proper base, that the floor protection extends far enough in front of the door, and that the clearance to nearby walls matches the label. Where a stove is missing that label, the clearance rules get stricter, and we will tell you what that means for where it sits. That way the repair also leaves the stove legal and safe in the spot it occupies.

Repair, Replace or Switch Fuel

A sound cast iron or steel stove can run for decades with new seals, bricks and glass. Still, there are times to think about a change. If the body has cracked through, or the stove is an older model that smokes no matter how it is run, replacement often makes more sense than another round of parts. Here the planning angle becomes useful. A newer wood stove burns far cleaner and uses less wood for the same heat. A gas insert or stove ends wood handling altogether and keeps working on the winter days when the air district bans wood burning. A pellet unit sits in between: wood-based fuel, but fed by a motor and lit with a button. We price the repair and the alternatives together so the choice rests on real figures rather than guesses.

For anyone keeping their wood heater, the season is easier when it starts with a sweep and a look at the stove's moving parts. Stoves that burn often benefit from a check of the door seal and baffle each fall. We can do both on one visit, and the sweep part is priced from $415. When you book through the contact page, tell us whether you have a free-standing stove or an insert, the make if you know it, and what it is doing that it should not. If there was a chimney fire, say so, since that changes what we check first and may call for a Level 2 inspection before the stove is used again. Smoke spilling from the door or a fire that will not settle down are good reasons to call before the next cold spell rather than after.

How Braxton Chimney Works Works

NFPA 211 Levels

The inspection level picked to match the plan for the flue

Sized to the Unit

Liners and clearances taken from the appliance manual

Figures on Paper

Options and costs written down before anything is ordered

Photos in the Report

Pictures of what we found and what we fitted

Other Services to Compare

Chimney Sweep

Brushing, a filtered vacuum and a written note on the flue before an insert, gas logs or another season of open fires.

Open →

Chimney Inspection

NFPA 211 Level 1, 2 or 3, written to answer one question: can this chimney take the upgrade you have in mind?

Open →

Chimney Repair

Brick, crown, cap and flue repairs that clear the way for an insert, a stove or a log set to go in.

Open →

Fireplace Inspection

Measured, inside-the-house look at firebox, damper, hearth and surround, done before you choose between an insert, logs or staying open.

Open →

Fireplace Repair

Firebox, damper and hearth repairs, done so the fireplace can stay open now or take an insert later without rework.

Open →

Chimney Level 2 Inspection

Camera inspection from firebox to cap, with attic and roof checks, booked before relining, fitting an insert or selling.

Open →

Chimney Cap Installation

Stainless or copper caps fitted over the flue, or over a new liner's top plate once an insert goes in.

Open →

Chimney Flashing Repair

New step and counter flashing where chimney meets roof, cut into the mortar rather than smeared on with sealant.

Open →

Chimney Masonry Repair

Repointing, brick replacement and flaked face repair, with a mortar soft enough to suit the brick already in the wall.

Open →

Chimney Rebuilds

Upper stacks or whole chimneys relaid when the brick has loosened, often with a liner sized for a planned insert.

Open →

Fireplace Cleaning

Firebox emptied of ash, then soot and smoke staining wiped from the glass doors and the face around the opening.

Open →

Gas Fireplace Cleaning

Yearly service for gas logs, inserts and direct-vent units: burner, pilot, glass and vent looked after in one visit.

Open →

Gas Fireplace Repair

Pilot, ignition, valve and fan faults on gas inserts, log sets and built-in gas fireplaces, found by testing first.

Open →

Fireplace Remodel

A new face, hearth and mantel designed together with the insert or gas unit that will sit inside them.

Open →

Fireplace Inserts

Wood, gas and pellet inserts compared, sized to your opening and fitted with a liner up to the top of the chimney.

Open →

Pellet Stove Repair

Pellet stoves and pellet inserts that stop feeding, fail to light or quit mid-burn, traced part by part.

Open →

Gas Logs

Log sets chosen for your firebox and the way you use the room, with the gas line and venting checked first.

Open →

Chimney Seismic Retrofit

Bracing, strapping or a lighter rebuild above the roof for brick chimneys at risk in a strong quake.

Open →

Chimney Crown Repair

Split crowns sealed or poured new, so rain stays off the brick and out of the space around a new liner.

Open →

Dryer Vent Cleaning

Lint cleared from the dryer duct between the machine and the outside hood, with airflow confirmed at the end.

Open →

Chimney Liner Installation

A stainless liner matched to the appliance outlet, so an insert, stove or gas unit vents cleanly out the top.

Open →

Chimney Leak Repair

Damp stains, drips and rust in the firebox followed back to where the water enters, then fixed there.

Open →

Chimney Waterproofing

A breathable repellent for thirsty brick, used as the last step once the masonry repairs are finished.

Open →

Chimney Damper Repair

Throat dampers freed, rebuilt or replaced, and top-mounted dampers fitted where an open fireplace stays in use.

Open →

Chimney Chase Cover

Sagging or rusted tops on framed chimneys swapped for a stainless cover made for that chase.

Open →