Professional chimney service

A Fireplace Inspection That Answers Two Questions

Start With the Fireplace

Insert Options Compared
Written Quote Before Work
Photos With Every Report
NFPA 211 Inspection Levels
Liners Sized to the Appliance
Based in La Mirada
Insert Options Compared
Written Quote Before Work
Photos With Every Report
NFPA 211 Inspection Levels
Liners Sized to the Appliance
Based in La Mirada

What the Work Includes

Before anyone sells you a unit, the firebox has to be measured and judged. We look at the firebrick and its joints, the damper, the hearth extension, and the gap between the opening and any mantel or wooden trim. On a prefab box we read the label and check the panels. The report gives the opening's sizes next to the condition notes, so it doubles as the starting sheet for an insert quote.

Firebrick and mortar joints probed
Damper movement and seal noted
Hearth extension and trim clearances measured
Factory-built units identified by label
Opening sizes recorded for insert planning

Where a Fireplace Inspection Looks

A chimney inspection follows the flue to the top. A fireplace inspection spends its time in the room, on the parts you light a fire in and sit next to. We start with the firebox: the firebrick on the back and side walls, the mortar joints between them, and the floor where the grate sits. Then the hearth, inside and out, since a split slab is a path for a stray coal to reach the subfloor. We work the damper and look at the lintel over the opening for sagging or rust. A tape on the mantel shelf and the wooden trim tells us whether they sit far enough back for the fire you burn. On a factory-built unit, we look at the metal panels, the screen and the label that says which parts belong to it.

For owners who are thinking about an upgrade, we add the measurements that matter for one. An insert needs a certain width, height and depth, and some models also need a minimum width at the back of the firebox, which on older brick fireplaces is often narrower than the front. A gas log set needs enough depth for the burner and enough room above for the flame. A factory-built fireplace may only accept inserts its maker has listed for it, so we read the label and tell you where that leaves you. These numbers go in the same report as the safety findings. You end up with one page covering whether tonight's fire is a good idea and which kinds of upgrade it could take. If the numbers say no insert will fit, we tell you that plainly too.

Masonry Boxes and Metal Boxes

Most fireplaces in La Mirada and Whittier fall into one of two families, and they age in different ways. A masonry fireplace was built in place by a mason, with firebrick inside, common brick behind, and a clay flue above. It wears at the joints and the firebrick, slowly, and most of what goes wrong can be repaired. A factory-built fireplace came as a steel box with a listed metal chimney, framed into a wall and finished to look like masonry. Tract homes and condos from the seventies onward are full of them. Their panels crack, their screens and doors warp, and their parts are made by one company. When that company no longer makes a part, the repair choices narrow. Knowing which family you have is the first line of our report.

The family also shapes the upgrade path. A sound masonry fireplace can usually take a wood, gas or pellet insert with a liner, and the old box stays as the shell around it. A factory-built unit is more limited. Some accept a listed insert, many accept only the log sets their maker approved, and some are better removed and replaced with a new unit made for the job. When we inspect one, we say which of these applies to yours and why. For homes being sold, landlords with fireplaces in rental units, and owners simply planning ahead, that clarity saves calls to dealers who can only see a photo. Booking is through the contact page. Tell us roughly when the house was built and whether the fireplace has brick inside or metal panels.

How Braxton Chimney Works Works

NFPA 211 Levels

The inspection level picked to match the plan for the flue

Sized to the Unit

Liners and clearances taken from the appliance manual

Figures on Paper

Options and costs written down before anything is ordered

Photos in the Report

Pictures of what we found and what we fitted

Other Services to Compare

Chimney Sweep

Brushing, a filtered vacuum and a written note on the flue before an insert, gas logs or another season of open fires.

Open →

Chimney Inspection

NFPA 211 Level 1, 2 or 3, written to answer one question: can this chimney take the upgrade you have in mind?

Open →

Chimney Repair

Brick, crown, cap and flue repairs that clear the way for an insert, a stove or a log set to go in.

Open →

Fireplace Repair

Firebox, damper and hearth repairs, done so the fireplace can stay open now or take an insert later without rework.

Open →

Chimney Level 2 Inspection

Camera inspection from firebox to cap, with attic and roof checks, booked before relining, fitting an insert or selling.

Open →

Chimney Cap Installation

Stainless or copper caps fitted over the flue, or over a new liner's top plate once an insert goes in.

Open →

Chimney Flashing Repair

New step and counter flashing where chimney meets roof, cut into the mortar rather than smeared on with sealant.

Open →

Chimney Masonry Repair

Repointing, brick replacement and flaked face repair, with a mortar soft enough to suit the brick already in the wall.

Open →

Chimney Rebuilds

Upper stacks or whole chimneys relaid when the brick has loosened, often with a liner sized for a planned insert.

Open →

Fireplace Cleaning

Firebox emptied of ash, then soot and smoke staining wiped from the glass doors and the face around the opening.

Open →

Gas Fireplace Cleaning

Yearly service for gas logs, inserts and direct-vent units: burner, pilot, glass and vent looked after in one visit.

Open →

Gas Fireplace Repair

Pilot, ignition, valve and fan faults on gas inserts, log sets and built-in gas fireplaces, found by testing first.

Open →

Fireplace Remodel

A new face, hearth and mantel designed together with the insert or gas unit that will sit inside them.

Open →

Fireplace Inserts

Wood, gas and pellet inserts compared, sized to your opening and fitted with a liner up to the top of the chimney.

Open →

Pellet Stove Repair

Pellet stoves and pellet inserts that stop feeding, fail to light or quit mid-burn, traced part by part.

Open →

Wood Stove Repair

Door rope, glass, baffles, firebrick and combustors renewed on wood stoves and wood inserts, plus the joint to the flue.

Open →

Gas Logs

Log sets chosen for your firebox and the way you use the room, with the gas line and venting checked first.

Open →

Chimney Seismic Retrofit

Bracing, strapping or a lighter rebuild above the roof for brick chimneys at risk in a strong quake.

Open →

Chimney Crown Repair

Split crowns sealed or poured new, so rain stays off the brick and out of the space around a new liner.

Open →

Dryer Vent Cleaning

Lint cleared from the dryer duct between the machine and the outside hood, with airflow confirmed at the end.

Open →

Chimney Liner Installation

A stainless liner matched to the appliance outlet, so an insert, stove or gas unit vents cleanly out the top.

Open →

Chimney Leak Repair

Damp stains, drips and rust in the firebox followed back to where the water enters, then fixed there.

Open →

Chimney Waterproofing

A breathable repellent for thirsty brick, used as the last step once the masonry repairs are finished.

Open →

Chimney Damper Repair

Throat dampers freed, rebuilt or replaced, and top-mounted dampers fitted where an open fireplace stays in use.

Open →

Chimney Chase Cover

Sagging or rusted tops on framed chimneys swapped for a stainless cover made for that chase.

Open →
Call (562) 449-0662